Description

The Juntek JDS2900 is a functional generator of standard and arbitrary waveforms from Hangzhou Juncea Instruments. The signal generator has two channels completely independent of each other, with complete accurate adjustment of amplitude and offset. A large number of built-in waveforms and types of modulation, allow you to use this device for measuring tasks of varying complexity. In addition, the generator is equipped with a built-in hardware frequency meter and a pulse counter that allows frequency measurements, counting the number of pulses in the frequency range: from 1 Hz to 100 MHz. An important feature of the JUNGE JDS2900 is the possibility of linear and logarithmic scanning, high measurement accuracy, pulse generation. The device is equipped with a memory capable of storing signals with a length of 2048 points. The device is truly versatile, meets all safety rules, is easy to use and has a long service life.

  • The device has a built-in frequency meter up to 100 MHz and a pulse counter, as well as an amplitude modulation function and a frequency sweep function. Both output channels CH1 and CH2 are fully functional and independent of each other. The frequency, amplitude and offset of the signal are set separately.
  • All measured parameters are displayed on a digital 2.4-inch TFT display. Thanks to the included software, all data is stored and exported to a PC. It is also possible to carry out measurements remotely and observe the results from your computer screen.
  • The USB interface allows users to transfer data to a PC, as well as to produce power from an external battery.

                        Frequency Specifications

JDS2900 – 15 M

JDS2900 – 30 M

JDS2900 – 40 M

JDS2900 – 50 M

JDS2900 – 60 M

Sine Wave Frequency Range

0 – 15 MHz

0 – 30 MHz

0 – 40 MHz

0 – 50 MHz

0 – 60 MHz

Square Wave Frequency Range

0 – 15 MHz

0 – 25 MHz

0 – 25 MHz

0 – 25 MHz

0 – 25 MHz

Triangle Wave Frequency Range

Pulse Wave Frequency Range

0 – 6 MHz

0 – 6 MHz

0 – 6 MHz

0 – 6 MHz

0 – 6 MHz

TTL Digital Wave Frequency Range

Arbitrary Frequency Fange

Pulse width Adjustment Range

100 nS – 4000 S

50 nS – 4000 S

40 nS – 4000 S

30 nS – 4000 S

25 nS – 4000 S

Square Wave Rise Time

≤ 25 ns

≤ 15 ns

≤ 10 ns

≤ 10 ns

≤ 10 ns

Minimum Frequency Resolution

0.01 uHz(0.00000001 Hz)

Frequency Accuracy

± 20 ppm

Frequency Stability

±1 ppm / 3 hours

                                 Waveform Specifications

Waveform Type

SineSquare、pulse (adjustable duty cycle, precise adjustment of pulse width and period), triangular wave, partial sine wave, CMOS wave, DC level (set DC amplitude by adjusting offset), half wave, full Wave, positive staircase wave, anti-ladder wave, noise wave, exponential rise, exponential drop, multisonic wave, Symplectic pulse and Lorenz pulseand 60 arbitrarywave forms.

Wave Length

2048 points

Waveform Sampling Rate

266 MSa / s

Waveform Vertical Resolution

14 bits

Square Wave and Pulse Wave

Overshoot

≤ 5 %

Pulse Wave

Duty Cycle Adjustment Range

0.1 % – 99.9 %

Partial Sine Wave

Duty Cycle Adjustment Range

0.1 % – 99.9 %

Sine Wave

Harmonic Suppression

≥ 45 dBc (< 1 MHz), ≥ 40 dBc (1 MHz- 20 MHz)

Total Harmonic Distortion

< 1 % (20 Hz- 20 kHz, 0 dBm)

Saw-Tooth Wave

Linearity

≥ 98 %(0.01 Hz – 10 kHz)

                                      Output Specifications

Sine Wave Amplitude Range

Frequency < 11 MHz

11 MHz  ≤ Frequency < 31 MHz

31 MHz ≤ Frequency

2 mVpp – 20 Vpp

2 mVpp – 10 Vpp

2 mVpp – 5 Vpp

Squarewave / Triangle Wave

Amplitude Range

Frequency ≤ 10 MHz

10 MHz ≤ Frequency  ≤ 25 MHz

2 mVpp – 20 Vpp

2 mVpp – 10 Vpp

Amplituderesolution

1 mV

Amplitudestability

± 0.5 % / 5 hours

Flatness Ofamplitude

± 5 % (<10 MHz), ± 10 % (> 10 MHz)

Waveform Output

Outputimpedance

50 Ω ± 10 % (typical)

Protection

All signal outputs can work within 60 seconds when the load is short-circuited.

                   DC Offset

Offsetadjustment range

|Offset| ≤ 10 – ampilitude / 2

Offset Resolution

0.01 V

                                 Phase Specifications

Phaseadjustment Range

0 – 359.9°

Phase Resolution

0.1°

                               TTL / CMOS Output

Low Level

< 0.3 V

High Level

1 V – 10 V

Level Rise / Fall Time

≤ 20 ns

                                   External Measurement Function

Frequencymeter Function

Frequency Measurement Range

1 Hz – 100 MHz

Measurement Accuracy

Gate time 0.01 S – 10 s continuously adjustable

Counter Function

Counting Range

0 – 4294967295

Coupling Method

DC and AC coupling methods

Counting Method

Manually

Input Signal Voltage Range

2 Vpp – 20 Vpp

Pulse width Measurement

0.01 us resolution, measure up to 20 s

Period Measurement

0.01 us resolution, measure up to 20 s

                              Sweep Function

Sweep Channel

CH1 or CH2

Sweep Type

Linear sweep, logarithmic sweep

Sweep Time

0.1 s – 999.9 s

Setting Range

Any setting between the maximum output frequency of the corresponding model of the starting point (0.01 Hz) and the end point

Sweep Direction

Forward, reverse and round trip

                                Bursting Function

Number of Pulses

1 – 1048575

Burst Mode

Manual burst, CH2 burst, external burst (AC), external burst (DC)

                           General Specifications

Display

Display type

2.4 inch TFT color LCD display

Store and Load

Quantity

100

Position

00 to 99 (00 memory location parameter is loaded by default as power on)

Arbitrary Wave

Quantity

1 to 60 total 60 groups (15 groups by default as power on)

Interface

Interface mode

USB to serial interface

Extension interface

With TTL level mode serial interface for user secondary development

Communication speed

Adopt standard 115200 bps

Protocol

Using the command line, the protocolis made public

Power Supply

Voltage range

DC 5 V ± 0.5 V

Manufacturing Technology

Surface mount technology, large-scale integrated circuits, high reliability, long service life

Prompt Tone

Users can turn on or off by setting program

Operating Specifications

All key operations, knob continuous adjustment

Environmental Conditions

Temperature: 0 – 40 ℃ Humidity: < 80 %